Skip to content
Skip to content
  • News
  • Events
  • eBooks
  • Blog
  • Careers
  • Contact
  • News
  • Events
  • eBooks
  • Blog
  • Careers
  • Contact
KNOWLEDGEBASE
  • About Us
  • Products

    Fluorescence Spectrometers

    • FLS1000 Photoluminescence Spectrometer
    • FS5 Spectrofluorometer
    • LifeSpec II Lifetime Spectrometer
    • Mini-tau Lifetime Spectrometer

    Raman Microscopes

    • RM5 Raman Microscope
    • RMS1000 Multimodal Confocal Microscope

    Transient Absorption

    • LP980 Transient Absorption Spectrometer

    FTIR Spectrometers

    • IR5 FTIR Spectrometer

    Lasers and LEDs

    • Pulsed Lasers
    • Gas Lasers
    • Customisation Options
    View All Products
  • Techniques
  • Applications
KNOWLEDGEBASE
Edit Content
  • About Us
  • Products
  • Techniques
  • Applications
  • Knowledgebase
  • eBooks
  • News
  • Events
  • Blog
  • Careers
  • Contact Us

RESOURCES

What is Multichannel Scaling (MCS)?

  • July 20, 2023

KEY POINTS

  • Multi­channel scaling can greatly reduce acquisition times for samples compared to time­ correlated single­ photon counting. 
  • Ideal for phosphorescent samples like metal complexes and singlet oxygen. 
  • Multi­channel scaling is not limited to the 5% count rate limit of time­ correlated single­ photon counting. 
  • Most useful for lifetimes above 100 ns. 
  • No dead time losses. 
Edit Content

Multi­channel Scaling (MCS) is a photon counting method for measuring phosphorescence lifetimes. Multiple photons are collected in each sweep of the time window to quickly accumulate decays across times scales from several hundred nanoseconds to seconds. 

How Does MCS Work?

In an MCS measurement a pulsed excitation source such as a laser or flashlamp is used to excite the sample and the resulting photoluminescence decay is recorded. The operation of an MCS measurement is shown in Figure 1 and is based on a time sweep that sorts the detected photons into different arrival time channels to create a histogram of the photoluminescence decay. The system comprises of a detector for the emitted photons, which passes the voltage to the constant fraction discriminator (CFD) which produces an electronic signal independent of amplitude. These electronic signals are sorted into bins within the memory (MEM) to form the histogram of time against intensity. 

Simplified overview of MCS with two inputs

Figure 1. Simplified overview of MCS with two inputs (SWEEP START and Sample SIGNAL) producing a histogram of timed events binned into channels split evenly across the time range.​1​ 

The measurement time window is split into channels as shown in Figure 2. A time sweep is started, and the excitation pulse excites the sample. The sweep starts at channel 1 and any photons that arrive during channel 1 are recorded in the memory, the sweep moves onto channel 2 and the photons that arrive during channel 2 are recorded and so on until the sweep has covered the entire window. In Figure 2, two time sweeps are shown, and 11 photons are recorded.  

An example of MCS

Figure 2. An example of MCS. The time window (orange) is swept by collecting counts within a set number of channels (blue) multiple times to build up the decay. Photons 2 and 3 arrive within the same channel and therefore appear as arriving at the same time. 

When multiple photons arrive within the same channel they are recorded as having the same arrival time. The time resolution of the MCS measurement is determined by the time width of the channels in the sweep. Time resolution can be increased by adding more channels, which is typically limited to a maximum time resolution due to constraints on the electronics. This lack of temporal resolution makes MCS unsuitable for photoluminescent decays with lifetimes under 100 ns such as fluorescent emitters, but it is ideal for phosphorescent emitters.  

MCS Decay Example

An example of a single exponential phosphorescent decay acquired using MCS is shown in Figure 3. The data has been tail fitted from the peak of the decay to the baseline to give a single 119 µs lifetime component. 

Phosphorescence decay of a Europium complex

Figure 3. Phosphorescence decay of a Europium complex (blue), the single exponential tail fit (red), and the residuals of this fit (grey). Measured on an FS5 Spectrofluorometer using a Xenon microsecond flashlamp for excitation. 

Can You Separate Fluorescence and Phosphorescence? 

Samples may exhibit short, fluorescent decays and longer phosphorescent decays. Both cannot be recorded in high resolution simultaneously, but MCS may be used to isolate the phosphorescent components by using time gating. Time gating removes the fluorescent components from the histogram by switching off the detector at earlier arrival times, effectively blinding the detector to these photons.  

Time ­Correlated Single ­Photon Counting vs Multi­channel Scaling

An alternative approach to recording photoluminescence decays is the more common time-correlated single­ photon counting (TCSPC) technique. The key difference between TCSPC and MCS is that in TCSPC only a maximum of one emitted photon can be detected per excitation pulse, while MCS can detect multiple photons per excitation pulse.  

In TCSPC the emission count rate must stay below 5% of the laser repetition rate to reduce the probability of multiple emitted photons arriving at the detector and being missed. If higher count rates are used, pulse pile-up occurs, which causes the recorded decay to be skewed to a shorter decay time.​1–3​ This is shown in Figure 4, where only two STOP signals are recorded for 6 excitations of the sample.   

TCSPC Method

Figure 4. TCSPC method where a pulsed laser starts the counting, and a single detected photon acts as the stop signal. 

When measuring short fluorescence lifetimes TCSPC acquisition times are quick as high repetition rate MHz lasers can be used to record millions of photons of the decay within seconds despite this 5% limit. However, it becomes increasingly slow for measuring longer lifetimes as the laser repetition rate must be decreased. Phosphorescence emitters with lifetimes in the hundreds of microseconds to milliseconds would take hours or even days to acquire using TCSPC.   

Because MCS can record multiple photons per excitation cycle, the acquisition time is much lower than in TCSPC, especially when measuring long lifetime decays. The downside of MCS is that it has reduced temporal resolution compared to TCSPC. MCS is therefore the optimum technique for measuring longer-lifetime phosphorescent samples where the femtosecond time resolution of TCSPC is not required, and the higher acquisition speed of MCS is a clear advantage.  

Table 1. Comparison of TCSPC and MCS. 

MethodPhotoluminescenceRecorded LifetimesResolutionRepetition Rates
TCSPCFluorescenceps, nsHigherHigher
MCSPhosphorescenceµs, ms, sLowerLower

References

​​1 W. (Wolfgang) Becker, Advanced time-correlated single photon counting techniques, Springer, 2005. 

​2 W. Becker, The bh TCSPC Handbook, 8th edn., 2019. 

​3 J. R. Lakowicz, Principles of Fluorescence Spectroscopy Third Edition, 2010. 

PrevPrevious
NextNext
Previous Illumination Techniques in Optical Microscopy Next Photoluminescence and Electroluminescence Confocal Imaging of an OLED

RESOURCES

Tags:
  • Spectral School
  • FLS1000
  • FS5
  • Photoluminescence
Suggested Reading:

Photoluminescence and Electroluminescence Confocal Imaging of an OLED

View more »

What is the Difference between Luminescence, Photoluminescence, Fluorescence, and Phosphorescence?

View more »

Measuring Fluorescence and Phosphorescence Spectra at Low Temperature Using the FLS1000 Photoluminescence Spectrometer

View more »
Share:

Keep up to date with the latest from Edinburgh Instruments

Join our mailing list and keep up with our latest videos, app notes and more!

LOCATION:
  • Edinburgh Instruments Ltd.
    2 Bain Square, Kirkton Campus, Livingston, EH54 7DQ.
  • sales@edinst.com
  • +44 1506 425 300
ABOUT:
  • About Us
  • Techniques
  • Applications
  • Knowledgebase
  • About Us
  • Techniques
  • Applications
  • Knowledgebase
PRODUCTS:
  • Fluorescence Spectrometers
  • Raman Microscopes
  • UV-Vis Spectrophotometers
  • Transient Absorption
  • FTIR Spectrometers
  • Lasers and LEDs
  • Customisation Options
  • Software
  • Upgrades
  • All Products
  • Fluorescence Spectrometers
  • Raman Microscopes
  • UV-Vis Spectrophotometers
  • Transient Absorption
  • FTIR Spectrometers
  • Lasers and LEDs
  • Customisation Options
  • Software
  • Upgrades
  • All Products
LEGALS:
  • News
  • Events
  • Blog
  • Careers
  • Contact Us
  • Terms and Conditions
  • Privacy Policy
  • News
  • Events
  • Blog
  • Careers
  • Contact Us
  • Terms and Conditions
  • Privacy Policy
SOCIALS:
Youtube Linkedin X-twitter Facebook
©2024 Edinburgh Instruments. Registered in England and Wales No: 962331. VAT No: GB 271 7379 37
Manage Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behaviour or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
Manage options Manage services Manage {vendor_count} vendors Read more about these purposes
View preferences
{title} {title} {title}