Skip to content
Skip to content
  • News
  • Events
  • eBooks
  • Blog
  • Careers
  • Contact
  • News
  • Events
  • eBooks
  • Blog
  • Careers
  • Contact
KNOWLEDGEBASE
  • About Us
  • Products

    Fluorescence Spectrometers

    • FLS1000 Photoluminescence Spectrometer
    • FS5 Spectrofluorometer
    • LifeSpec II Lifetime Spectrometer
    • Mini-tau Lifetime Spectrometer

    Raman Microscopes

    • RM5 Raman Microscope
    • RMS1000 Multimodal Confocal Microscope

    Transient Absorption

    • LP980 Transient Absorption Spectrometer

    FTIR Spectrometers

    • IR5 FTIR Spectrometer

    Lasers and LEDs

    • Pulsed Lasers
    • Gas Lasers
    • Customisation Options
    View All Products
  • Techniques
  • Applications
KNOWLEDGEBASE
Edit Content
  • About Us
  • Products
  • Techniques
  • Applications
  • Knowledgebase
  • eBooks
  • News
  • Events
  • Blog
  • Careers
  • Contact Us

RESOURCES

Instrument Response Function Widths & Minimum Measurable Lifetimes in the FLS1000

  • June 9, 2023
Edit Content

What is the Instrument Response Function?

Short lifetimes in the FLS1000 are measured using the time-correlated single photon counting (TCSPC) technique. The minimum measurable lifetime in TCSPC depends on the temporal width of the Instrument Response Function (IRF) which is a measure of the total response time of the TCSPC excitation and detection system.

The IRF has four main contributions and the total IRF temporal width can be calculated by the quadrature summation of the individual contributions. All widths are given as the full-width half maximum (FWHM) of their temporal distributions:

Equation to calculation total instrument response function temporal width.

FWHMSource is the pulse width of the excitation source which is typically a pulsed laser. The pulse width depends on the type and model of the laser used.

FWHMDetector is the response width of the detector and depends on the type of detector used. This is often the dominant contribution to the total width of the IRF.

FWHMElectronics is the electronic jitter of the TCSPC timing electronics. The jitter of FLS1000 TCC2 counting electronics is 20 ps and electronic jitter is therefore only significant when the FHWMSource ­­and FHWMDetector are small.

FWHMDispersion is the temporal dispersion of the pulse as it passes through the emission monochromator. Dispersion is only significant when FHWMSource ­­and FHWMDetector are small. When the FLS1000 is configured with a fast detector (small FHWMDetector) a low groove density lifetime grating is added to the emission monochromator to minimise FWHMDispersion.

The source pulse widths, detector response widths and total FWHMIRF of the source and detector combinations that are possible in the FLS1000 are given in Table 1. The pulse widths of the sources are approximate as the exact pulse widths are dependent on the wavelength of the source.

Table 1: FWHMIRF of source and detector combinations in the FLS1000.

Table of FWHM (IRF) of source and detector combinations in the FLS1000.

Minimum Lifetimes

Short lifetimes are calculated using reconvolution fitting. In reconvolution fitting, the IRF is measured experimentally and convoluted with the chosen decay model prior to fitting to take into account the width and shape of the IRF during the fitting routine. The width and shape of the IRF determines the minimum lifetime that can be reliably extracted using reconvolution fitting.

FWHMIRF / 10

One-tenth of the FWHMIRF is the most often quoted minimum lifetime achievable via reconvolution fitting. While technically possible, this minimum lifetime is achievable only under ideal experimental conditions. The sample must be a solution and the decay to be fitted must exhibit single exponential kinetics, and even under these conditions careful measurements are required to reach this limit. Multi-component exponential fits are not possible at this limit as they have too many degrees of freedom and solid samples have unpredictable scattering properties during the IRF acquisition for the one-tenth limit to be reliable.

FWHMIRF / 3

One-third of the FWHMIRF is a more practical estimate of the minimum lifetime that can be achieved via reconvolution fitting.  Staying within this limit increases the fit reliability when measuring solutions with single exponential kinetics and enables solutions with multiexponential kinetics to also be fit. Analysis of decays of solid samples with single exponential kinetics is also possible within this limit. In general, when analysis of samples with complicated kinetics is expected; configure the FLS1000 to have as narrow a FWHMIRF as possible to increase the reliability of the fitting and reduce the experimental complexity of the measurements.

Conclusion

The width of the IRF is the key metric that determines the minimum measurable lifetime in the FLS1000.  The FLS1000 can be equipped with a wide range of sources and detectors that enable IRF widths as low as 30 ps to be achieved. It is recommended to configure the FLS1000 sources and detectors with at least the FWHMIRF / 3 minimum lifetime limit in mind.

RELATED PRODUCTS

FLS1000

Photoluminescence Spectrometer

VIEW

Contact our expert team today to find out more about how our products can improve your research

Contact Us
PrevPrevious
NextNext
Previous Photoluminescence Spectroscopy Poster Presentation Series – TADF Emitter Characterisation Next TCSPC – What is Time-Correlated Single Photon Counting?

RESOURCES

Tags:
  • Technical Notes
  • TCSPC
  • FLS1000
Technical Note:
Download PDF
Suggested Reading:

High-Speed Hybrid Photodetector (HS-HPD)

View more »

Measuring Picosecond Fluorescence Lifetimes Using the FLS1000 Equipped with a Hybrid Photodetector

View more »
Share:

Keep up to date with the latest from Edinburgh Instruments

Join our mailing list and keep up with our latest videos, app notes and more!

LOCATION:
  • Edinburgh Instruments Ltd.
    2 Bain Square, Kirkton Campus, Livingston, EH54 7DQ.
  • sales@edinst.com
  • +44 1506 425 300
ABOUT:
  • About Us
  • Techniques
  • Applications
  • Knowledgebase
  • About Us
  • Techniques
  • Applications
  • Knowledgebase
PRODUCTS:
  • Fluorescence Spectrometers
  • Raman Microscopes
  • UV-Vis Spectrophotometers
  • Transient Absorption
  • FTIR Spectrometers
  • Lasers and LEDs
  • Customisation Options
  • Software
  • Upgrades
  • All Products
  • Fluorescence Spectrometers
  • Raman Microscopes
  • UV-Vis Spectrophotometers
  • Transient Absorption
  • FTIR Spectrometers
  • Lasers and LEDs
  • Customisation Options
  • Software
  • Upgrades
  • All Products
LEGALS:
  • News
  • Events
  • Blog
  • Careers
  • Contact Us
  • Terms and Conditions
  • Privacy Policy
  • News
  • Events
  • Blog
  • Careers
  • Contact Us
  • Terms and Conditions
  • Privacy Policy
SOCIALS:
Youtube Linkedin X-twitter Facebook
©2024 Edinburgh Instruments. Registered in England and Wales No: 962331. VAT No: GB 271 7379 37
Manage Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behaviour or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
Manage options Manage services Manage {vendor_count} vendors Read more about these purposes
View preferences
{title} {title} {title}