Skip to content
  • News
  • Events
  • eBooks
  • Blog
  • Careers
  • Contact
  • News
  • Events
  • eBooks
  • Blog
  • Careers
  • Contact
KNOWLEDGEBASE
  • About Us
  • Products

    Fluorescence Spectrometers

    • FLS1000 Photoluminescence Spectrometer
    • FS5 Spectrofluorometer
    • LifeSpec II Lifetime Spectrometer
    • Mini-tau Lifetime Spectrometer

    Raman Microscopes

    • RM5 Raman Microscope
    • RMS1000 Multimodal Confocal Microscope

    Transient Absorption

    • LP980 Transient Absorption Spectrometer

    FTIR Spectrometers

    • IR5 FTIR Spectrometer

    Lasers and LEDs

    • Pulsed Lasers
    • Gas Lasers
    • Customisation Options
    View All Products
  • Techniques
  • Applications
KNOWLEDGEBASE
Edit Content
  • About Us
  • Products
  • Techniques
  • Applications
  • Knowledgebase
  • eBooks
  • News
  • Events
  • Blog
  • Careers
  • Contact Us

RESOURCES

Ramacle® Software Highlight: FastMAP®

  • August 4, 2022

KEY POINTS

  • FastMAP® in Ramacle® significantly reduces Raman mapping acquisition times by enabling continuous stage movement, eliminating the time spent on stage acceleration and deceleration.
  • FastMAP® is most effective for samples with strong Raman signals or photoluminescence, where short exposure times (<0.5 seconds) are used.
  • Compared to standard mapping, FastMAP® maintains map quality while drastically reducing acquisition time.
Edit Content

Ramacle® Software Highlight: FastMAP®

FastMAP® in Ramacle® enables the user to acquire Raman maps with significantly reduced acquisition times via more efficient stage movement.

Standard Mapping

In Raman mapping a sample is placed on the motorised stage under the microscope and the user defines the area to be mapped, and the number of measurement points i.e., the map resolution. During standard mapping the stage will stop at each measurement point, the laser is directed onto the sample, and its Raman spectrum acquired, Figure 1. The length of time the Raman spectrum is acquired for at each point is termed the exposure time and this can vary significantly from milliseconds to several seconds depending on the sample.

Standard MappingFigure 1: Standard mapping.

In the standard stage movement method, time is spent accelerating and decelerating the stage as it moves from point to point. The shorter the exposure time, the more significant this stage movement time is to the total acquisition time of the map. The standard mapping method is therefore best suited for samples with a weak Raman response that require long exposure times of >0.5 seconds where the total acquisition time of the map is governed by the exposure time rather than the stage movement.

When mapping samples with a strong Raman or photoluminescence response shorter exposure times of <0.5 seconds are routinely used. The standard method of stage movement will still produce high quality Raman maps, but the stage movement time will start to significantly increase the total map acquisition time. In this scenario a map which could theoretically take 15 minutes will take over one hour, due to the stage movement time.

FastMAP®

The solution to this is Ramacle’s® FastMAP® feature, where the stage continuously moves the sample during the map. With FastMAP®, the additional stage movement time is removed, and total acquisition times can be significantly reduced. FastMAP® is best suited for samples with a with a strong Raman or photoluminescence response when short exposure times can be used.

Fast MappingFigure 2: FastMAP®.

Raman Mapping Comparison

Using identical Raman conditions, a Raman map was taken of MoS2 with standard and FastMAP®. The total map acquisition time using standard mapping was 16 minutes and this was reduced to 4 minutes using FastMAP®.

Comparing Standard and Fast Raman Mapping

Figure 3: Comparison of identical map acquisition using standard mapping (left) and FastMAP® (right).

Despite obtaining the map 4 times faster using FastMAP®, there is no reduction in mapping quality, Figure 4. The MoS­2 maps from both mapping methods are comparable, revealing the same sample information. Raman mapping is used on MoS2 samples to show areas of mono- and multi-layers by the intensity of its E2g and A1g­ bands. Areas of higher intensity represent multi-layer MoS2.

Comparing intensity from Raman Imaging

Figure 4: Raman intensity maps of MoS2 using standard (left) and FastMAP® (right).

An additional advantage of FastMAP® is that it utilises a fast communication protocol between the stage and the CCD camera enabling shorter exposure times to be set by the user. Since the MoS2 sample has a strong Raman response the exposure time can be lowered to 0.01s resulting in a reduction of total map acquisition time to 1.5 minutes. With shorter exposure times there is a reduction in Raman signal, but for strongly Raman active samples, like MoS2, these short exposure times still provide sufficient information to obtain highly detailed Raman maps, Figure 5.

Raman intensity maps comparison | Raman Imaging

Figure 5: Raman intensity maps of MoS2 using standard (left), FastMAP®(centre), and FastMAP® with decreased exposure time (right).

Should I Use Standard or FastMAP®?

FastMAP® should be used for exposure times <0.5 seconds to reduce the total acquisition time of the map. Standard mapping is not optimum with exposure times <0.5 seconds as most of the mapping time is spent waiting on the stage to move rather than acquiring Raman spectra which is inefficient.

Standard mapping mode should be used for exposure times >0.5s. At this long an exposure time the stage must stop at each map point and the benefit of FastMAP® is removed and may cause a reduction in Raman signal with no benefit to the total acquisition time.

FastMAP® is available in Ramacle® for 2D and 3D Raman and Photoluminescence mapping using our RM5 and RMS1000 Confocal Raman Microscopes.

RELATED PRODUCTS

MicroPL

Spectromicroscopy Upgrade

VIEW

RMS1000

Multimodal Confocal Microscope

VIEW

Ramacle®

Software for the RM5 and RMS1000

VIEW

Contact our expert team today to find out more about how our products can improve your research

Contact Us
PrevPrevious
NextNext
Previous Rapid Excitation Emission Matrix Analysis of Single Wall Carbon Nanotubes Next Two-Photon Fluorescence Microscopy with the RMS1000 Confocal Microscope

RESOURCES

Tags:
  • Technical Notes
  • RM5
  • RMS1000
  • Photoluminescence
  • Raman
Software Highlight:
Download PDF
Suggested Reading:

Ramacle® Software Highlight: SurfMAP®

View more »
Share:

Keep up to date with the latest from Edinburgh Instruments

Join our mailing list and keep up with our latest videos, app notes and more!

LOCATION:
  • Edinburgh Instruments Ltd.
    2 Bain Square, Kirkton Campus, Livingston, EH54 7DQ.
  • sales@edinst.com
  • +44 1506 425 300
ABOUT:
  • About Us
  • Techniques
  • Applications
  • Knowledgebase
  • About Us
  • Techniques
  • Applications
  • Knowledgebase
PRODUCTS:
  • Fluorescence Spectrometers
  • Raman Microscopes
  • UV-Vis Spectrophotometers
  • Transient Absorption
  • FTIR Spectrometers
  • Lasers and LEDs
  • Customisation Options
  • Software
  • Upgrades
  • All Products
  • Fluorescence Spectrometers
  • Raman Microscopes
  • UV-Vis Spectrophotometers
  • Transient Absorption
  • FTIR Spectrometers
  • Lasers and LEDs
  • Customisation Options
  • Software
  • Upgrades
  • All Products
LEGALS:
  • News
  • Events
  • Blog
  • Careers
  • Contact Us
  • Terms and Conditions
  • Privacy Policy
  • News
  • Events
  • Blog
  • Careers
  • Contact Us
  • Terms and Conditions
  • Privacy Policy
SOCIALS:
Youtube Linkedin X-twitter Facebook
©2024 Edinburgh Instruments. Registered in England and Wales No: 962331. VAT No: GB 271 7379 37
Manage Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behaviour or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
Manage options Manage services Manage {vendor_count} vendors Read more about these purposes
View preferences
{title} {title} {title}